West 6010 Manual

Advertising
  1. West 6010 Manual Diagram
  2. West 6010 Manual Pdf
  3. West 6010 Manual
  4. West 6010 Manual Transmission
  5. West 6010 Manual Download
  6. 6010 Manual Us Navy

West Control Solutions 8700+ User Manual. 6 messages and error indications. West Control Solutions Equipment. TRICARE Policy Manual 6010.60-M, April 2015. These manuals are applicable to the East and West Regional Managed Care Support Contracts awarded on or after 07/21.

1

/

4

-DIN,

1

/

8

-DIN &

1

/

16

- DIN Controllers & Indicators - Product Manual


59305, Issue 7

– March 2014

Powering Up

Page 37

6 Messages and Error Indications

The following displays are shown when an error occurs or a hardware change is detected.

Table 4. Error/Faults conditions

Error/Faults Conditions

Upper display

Lower Display

(where fitted)

1

/

8

West 6010 Manual

DIN Indicator

Units Display

West 6010 Manual Diagram

Configuration & Setup is required.
Seen at first turn on or if hardware
configuration changed.

Press to enter Configuration
Mode,
next press or to enter the
unlock code number,
then press to proceed.

Configuration must be completed
before return to operator mode is
allowed

1



( for 1

second, then

 on

Indicators)





Input more than 5% over-range

2

West 6010 Manual Pdf

West 6010 Manual



*

Normal Display

Normal Display

Input more than 5% under-range

3



*

Normal Display

Normal Display

Sensor Break. Break detected in
the input sensor or wiring



*

Normal Display

Normal Display

Auxiliary input over-range

Normal Display



*

n/a

Auxiliary input under-range

Normal Display



*

n/a

Auxiliary Break. Break detected in
the auxiliary input

Normal Display



*

West 6010 Manual

n/a

Option 1 module fault.

**





Option 2 module fault.

**





Option 3 module fault.

**





Option A module fault.

**





Option B module fault.







* Note

Input sensor and Auxiliary over/under-range or break indications will be seen wherever
these values would normally be displayed.

** Note

Option module number follows error legend on

1

/

16

DIN Indicators (e.g. )

1

West 6010 Manual

This feature does not guarantee correct configuration. It only helps to ensure that the unit will be configured

before use. Use of set-up mode is not enforced but may be essential for the users application.

2

If the PV display exceeds



before 5% over-range is reached, an over-range indication is given.

3

Indicators will allow up to 10% under-range on non-zero based Linear ranges. If the PV display is less than

West 6010 Manual Transmission



before the % under-range is reached, an under-range indication is given.

Advertising
This manual is related to the following products:

West 6010 Manual Download

6700+, 4700+, 8010+, 6010+, 8170+, 8100+, 6170+, 6100+, 4170+, 4100+

6010 Manual Us Navy

Popular Brands
Popular manuals